An integrated water programme: from water balance to sewer system
- Client
- Aurubis Olen
- Sector
- Industry
- Services
- Key figure
- Overflows reduced from 19 to 1 in the simulation
The challenge
Aurubis Olen produces copper anodes, cathodes, wire and profiles. The site wanted to depend less on tower and canal water, avoid emergency discharges during heavy rain and prepare the sewer system for an expansion.
What we did
- Water balance identifying missing data, with a proposal for additional meters
- Rainwater simulation over six years and a disconnection plan with reuse in cooling towers and sprinkler systems
- Reuse of industrial wastewater: four technology routes, infrastructure plan, CAPEX and Water-as-a-Service
- Sizing of an influent buffer using four methods, including climate scenarios
- Hydraulic study of the sewer system and design for the expansion
Results
- UF with CCRO can cover the full demand of 361,413 m³ of tower and canal water per year with the site's own effluent
- A rainwater buffer of 5,500 m³ covers 100% of the sprinkler water (22,175 m³ per year)
- An influent buffer of ± 5,000 m³ reduces overflows in the simulation from 19 to 1
- Bottlenecks in the sewer system located, with cost estimates for an additional main collector
More references
Aluminium Duffel
79,000 m³/yr rainwater captured
Rainwater disconnection, capture and reuse plus a wastewater-reuse study with the neighbouring WWTP, for a European leader in rolled aluminium.
ViskoTeepak, Lommel
13+ technologies evaluated for compliance
End-of-pipe routes to remove sulphates and sulphides, selected from more than thirteen technologies with full CAPEX and OPEX per scenario.
Love Tomorrow (Tomorrowland)
Water footprint tracked per edition
A major festival measures its water footprint, sets out actions and tracks the results, edition after edition.
Facing a similar challenge?
Tell us about your site and we'll show you what's possible.